The motor and inverter show about 182–183 °C on a cold, parked bike and power is being cut. What is this and what should I check?

Most likely the temperature sensors (or their circuit) are lying, not a real overheat: ~183 °C is the top of the scale, and that is what a shorted sensor or circuit looks like. The bike believes these numbers: it limits power (alert 0x8000), runs the fan and pump, and the inverter shows code 0x4300.

What to do:

  1. In VargLink open "Diagnostics" → "Motor and inverter" and look at the three motor values and the three IGBT values.
  2. If only one sensor reads 183 °C, that sensor or its wire is faulty. If all three in a group read it, the problem is a common circuit (the motor–inverter signal connector or the measurement board in the inverter).
  3. Check "Inverter humidity" (above 55–70 % means water).
  4. Ask whether the bike was washed or ridden through water.
  5. Inspect and dry the motor–inverter signal connector.
  6. Switch the bike fully off for about 30 seconds, then switch it on again.

If the values still show ~183 °C on a cold bike, take it to a dealer (sensor or inverter). Riding it is not recommended.

from the Stark Varg chat
Didn't find an answer? Ask the bot @starkvarg_help_bot or the Stark Varg chat (in Russian).