The motor and inverter show about 182–183 °C on a cold, parked bike and power is being cut. What is this and what should I check?
Most likely the temperature sensors (or their circuit) are lying, not a real overheat: ~183 °C is the top of the scale, and that is what a shorted sensor or circuit looks like. The bike believes these numbers: it limits power (alert 0x8000), runs the fan and pump, and the inverter shows code 0x4300.
What to do:
- In VargLink open "Diagnostics" → "Motor and inverter" and look at the three motor values and the three IGBT values.
- If only one sensor reads 183 °C, that sensor or its wire is faulty. If all three in a group read it, the problem is a common circuit (the motor–inverter signal connector or the measurement board in the inverter).
- Check "Inverter humidity" (above 55–70 % means water).
- Ask whether the bike was washed or ridden through water.
- Inspect and dry the motor–inverter signal connector.
- Switch the bike fully off for about 30 seconds, then switch it on again.
If the values still show ~183 °C on a cold bike, take it to a dealer (sensor or inverter). Riding it is not recommended.
from the Stark Varg chat