What is known about the issue where the sensors for one half of the battery drop out while charging (after a firmware update)?
After a firmware update, half of the cells go offline in VargPilot and the bike stops charging. First half of the sensors drop out, then the BMS goes into protection, and for some reason the error gets logged against the inverter rather than the BMS. VargLink can now recognize the problem from indirect signs and shows a clear error message. The suspect is the ribbon cable between the two halves of the battery. A possible fix: open up the battery, reseat or clean the ribbon cable between the halves, and reassemble it with sealant. This is a suspicion, not a confirmed conclusion.