Why are cells #1, #50, #51 and #100 the ones that most often go out of sync in the battery data?
The battery is 100 series groups of 4 21700 cells each (400 cells in total). It is made up of two halves, each with its own BMS board (the logs show two firmware versions: bmsPos and bmsNeg). One board measures groups 1–50, the other measures groups 51–100. #1 and #100 are the ends of the chain at the power terminals. #50 and #51 are the joint between the halves, where the power jumper is. The outermost groups sit next to the contactors and the thick cables, so they run warmer when riding and charging, and they behave differently in the cold (on cold batteries the edge groups read above the median, on warm ones below it). The outermost channels of the BMS boards are tied to power and ground, so they are the first to pick up an offset.